28Ȧ¡¤(¼ÓÄôó)¹Ù·½ÍøÕ¾

    en Language
    • English English
    UT-TP120-25W£¬¿ª°åµçÔ´£¬DC-DCµçÔ´?

    UT-TP120-25W ¿ª°åµçÔ´

    ²úÆ·Ãû³Æ£º¿ª°åµçÔ´
    ¹æ¸ñÐͺÅ£ºUT-TP120-25W
    ÊÇ·ñ¶¨ÖÆ£ºÖ§³Ö¶¨ÖÆ»¯Éè¼Æ
    °²È«¹æ·¶£ºCEÈÏÖ¤
    ¹¤×÷ζÈ£º -40+85¡æ


    ²úÆ·¸ÅÊö£º

    UT-TP120-25WÊÇÒ»¸ö±ê×¼¹ìµÀ½»Í¨110VÊäÈëµÄDC-DCת»»µçԴϵÁÐÖеÄÒ»¿î²úÆ·£¬ÓÃÒÔʵÏÖ¸÷Àà¹ìµÀ½»Í¨µçÆ÷É豸ÄÚ²¿ÅäÖõÄDCµçѹת»»£¬±¾²úƷϵÁпÉÒÔ¸ù¾ÝÓû§µÄÐèÒª½øÐж¨ÖÆ»¯Éè¼ÆºÍÅäÖá£


    ²úÆ·ÌØÐÔ£º

    •  -40+85¡æ (Working Ambient temperature)µÄÕû»ú¹¤×÷»·¾³Î¶ȷ¶Î§

    • Ö§³ÖÊäÈ뵥·DCת»»³É¶à·DC¸ôÀëÊä³ö, Ö§³Ö³£¹æµçÔ´±£»¤£ºIRPPÊäÈë·´½Ó/OLP/OCP, ETC

    • Ö§³Ö¶¨ÖÆ»¯Éè¼ÆÅäÖÃÉè¼Æ


    ¹æ¸ñ²ÎÊý£º


    UT-TP120-25WµçÔ´°å¹¦ÄܲÎÊý
    Êä³ö¹¦Äܶ˿ںãѹ12VµçÔ´
    Ö±Á÷µçѹÎÈѹ12V
    ¶î¶¨µçÁ÷2.0A
    µçÁ÷·¶Î§0 ~ 2.5A
    ¶î¶¨¹¦ÂÊ25W
    ÎÆ²¨ÓëÔëÉù<25mVp-p
    µçѹµ÷Õû·¶Î§11.9V~12.4V
    ÎÈѹºãÁ÷¾«¶È¡À2.0%
    ÏßÐÔµ÷ÕûÂÊ¡À1.0%
    ¸ºÔص÷ÕûÂÊ¡À1.0%
    Æô¶¯¡¢ÉÏÉýʱ¼ä<15ms, 13ms/110VDC 
    ¹©µçÊäÈë Input supply
    µçѹ·¶Î§(72 ~ 144) VDC
    ƵÂÊ·¶Î§DC
    ЧÂÊ(Typ.)>=88%
    DCµçÁ÷<1.8A / 72VDC
    ÀËÓ¿µçÁ÷ÀäÆô¶¯<35A, VIN=110VDC
    ¹ýÔØ±£»¤< 160%
    ¿É×Ô¶¯»Ö¸´
    ¹ýѹ±£»¤N/A
    ±£»¤Ä£Ê½:¹Ø¶ÏÊä³ö£¬ÖØÆô¿É»Ö¸´
    ¹¤×÷ζÈ'-40¡«+85¡æ (Çë²Î¿¼"¼õ¶îÇúÏß")
    ¹¤×÷ʪ¶È20 ~ 90% RH,ÎÞÀäÄý
    ´¢´æÎ¶È¡¢Êª¶È-40 ~ +85¡æ, 10 ~ 95% RH,ÎÞÀäÄý
    ζÈϵÊý¡À0.03%/¡æ (0¡«50¡æ)
    ÄÍÕñ¶¯9 ~ 200Hz, 400m/s/s 10·ÖÖÓ/ÖÜÆÚ, X, Y, Z¸÷60·ÖÖÓ; °²×°: ·ûºÏIEC60068-2-6
    ²Ù×÷º£°Î2000Ã×
    °²È«¹æ·¶CEÈÏÖ¤
    ÄÍѹI/P-O/P:2.2KVDC;  I/P-EARTH:2.2KVDC
    ¾øÔµ×迹I/P-O/P:100M Ohms / 100VDC / 25¡æ/ 70% RH
    EMC²¿·ÖParameterStandardTest Level / Note
    EMIConductedEN55032(CISPR32)Class A
    RadiatedEN55032(CISPR32)Class A

    EMSµç´Å¼æÈÝ¿¹ÈÅ

    Harmonic CurrentEN61000-3-2Class A
    ESDEN61000-4-2Level 3, 8KV air; Level 2, 6KV contact, criteria A
    Radiated SusceptibilityEN61000-4-3Level 3, criteria A
    EFT/BurestEN61000-4-4Level 3, criteria A
    SurgeEN61000-4-5Level 4,2KV/L-N, criteria A
    ConductedEN61000-4-6Level 3, criteria A
    Magnetic FieldEN61000-4-8Level 4, criteria A
    Voltage Dips and interruptionsEN61000-4-11£¾95% dip 0.5 periods, 30% dip 25 periods,

    £¾95% interruptions 250 periods
    MTBF>=500K hrs min. MIL-HDBK-217F (25¡æ)
    ³ß´çSIDE102 x48 x(24+1.6+3) ¡À1mm (L*W*H)
     Weight¾»ÖØ0.05kg/Pcs
    1.   ÈçÎ´ÌØ±ð˵Ã÷£¬ËùÓйæ¸ñ²ÎÊý¾ùÔÚÊäÈëΪ110VDC¡¢¶î¶¨¸ºÔØ¡¢25¡æ»·¾³Î¶ÈϽøÐÐÁ¿²â¡£
    2.   ÎƲ¨ºÍÔëÉù²âÁ¿·½·¨£ºÊ¹ÓÃÒ»Ìõ12"Ë«½ÊÏߣ¬Í¬Ê±ÖÕ¶ËÒª²¢Áª0.1¦ÌFºÍ47¦ÌFµÄµçÈÝ£¬ÔÚ20MHz´ø¿íϽøÐÐÁ¿²â¡£
    3.   ¾«¶È£º°üº¬É趨Îó²î¡¢ÏßÐÔµ÷ÕûÂʺ͸ºÔص÷ÕûÂÊ¡£
    4.   µçÔ´±»ÊÓΪÊÇÒ»¸ö¶ÀÁ¢µÄÔª¼þ£¬µ«×îÖÕµçÔ´ÈÔÐè½áºÏÖÕ¶ËÉ豸½øÐеç´Å¼æÈÝÏà¹ØÈ·ÈÏ¡£  
    5.   µ±º£°Î¸ß¶È³¬¹ý2000Ã×(6500Ó¢³ß)ʱ£¬ÎÞ·çÉÈ»úÐÍ»·¾³Î¶ÈÒÀÿ3.5¡æ/1000m±ÈÀýϽµ£¬ÓзçÉÈ»úÐÍ»·¾³Î¶ÈÒÀÿ5¡æ/1000m±ÈÀýϽµ¡£
    ¡ù ²úÆ·ÃâÔðÉùÃ÷£ºÏêÇéÇë²ÎÔÄ Ê¹ÓÃ˵Ã÷Êé




    UT-TP120-25W¹æ¸ñÊé

    Îļþ´óС£º485KB

    ÊÊÓòúÆ·£ºUT-TP120-25W

    ¸üÐÂÈÕÆÚ£º2025-3-21

    °æ±¾ºÅ£ºV1.0

    ¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿